Ricoh M281 Series Service Manual page 488

Hide thumbs Also See for M281 Series:
Table of Contents

Advertisement

Service Call 622-691
SC No.
Type
SC668-00
D
SC No.
Type
SC669
SC669-01
D
SC669-02
D
SC669-03
D
SC669-04
D
SC669-05
D
SC669-06
D
SC669-07
D
SC669-08
D
SC669-09
D
SC669-10
D
SC669-11
D
SC669-12
D
SC669-13
D
D255/D256/M281/M282
Error Name/Error Condition/Major Cause/Solution
SPI Communication Error
The SPI communication error cannot be recovered within 10
seconds after the error occurred.
The error recovery does not finish normally.
FFC defective or disconnected
BiCU defective
IOB defective
1.
Turn the main power OFF/ON.
2.
Reconnect the FFC between BiCU and IOB.
3.
Replace the FFC between BiCU and IOB.
4.
Replace the BiCU.
5.
Replace the IOB.
Error Name/Error Condition/Major Cause/Solution
EEPROM Communication Error
EEPROM OPEN: ID error
EEPROM OPEN: Channel error
EEPROM OPEN: Device error
EEPROM OPEN: Communication abort error
EEPROM OPEN: Communication timeout error
EEPROM OPEN: Operation stopped error
EEPROM OPEN: Buffer full
EEPROM OPEN: No error code
EEPROM CLOSE: ID error
EEPROM CLOSE: No error code
EEPROM Data write: ID error
EEPROM Data write: Channel error
EEPROM Data write: Device error
6-50