SC No.
Type
SC689-02
D
SC No.
Type
SC690-00
C
SC No.
Type
SC691-00
D
SM
Error Name/Error Condition/Major Cause/Solution
EEPROM Communication Error 1
IOB defective
Controller board defective
Replace the controller board.
Error Name/Error Condition/Major Cause/Solution
EEPROM Data Error
Reading data from EEPROM is abnormal.
EEPROM on the controller board defective
1.
Turn the main power OFF and wait for 5 seconds. Then turn
the main power ON.
2.
Replace the IOB.
3.
If the EEPROM on the controller board is damaged, replace
the EEPROM.
Error Name/Error Condition/Major Cause/Solution
Image Processing Error
Paper jam (J010, J011, J012, J013, J014, J015) is detected
twice.
Controller board defective
Replace the controller board.
6-53
Service Call 622-691
D255/D256/M281/M282