SC No.
Type
SC543-00
D
SM
Error Name/Error Condition/Major Cause/Solution
Fusing Thermistor (Center) High Temperature
The fusing thermistor (center) detects the temperature that
exceeds 245 degrees C.
The fusing thermistor (center) detects the temperature that
exceeds 195 degrees C in a heater-off state after the fusing
thermistor (center) detects the temperature of 155 degrees
C or less.
Connector pin defective
Triac defective
Fusing thermistor defective
IOB defective
Connector pin defective
If the I/F connector pins of the fuser unit and the main unit
are deformed owing to foreign materials, replace the
connectors or the units including the connectors.
Triac defective
Disconnect the power cord and check that the resistance
between terminals T1 and T2 of the triac TRA31 and triac
TRA41 on the PSU are several Mega-Ohms and not
shorted. If failed, replace the PSU.
Fusing thermistor defective
Replace the fusing unit.
IOB defective
Replace the IOB.