Bit Switches - 4
Bit 1
Bit 0
0
0
0
1
1
0
1
1
2
Select cancellation of high-speed RX
if carrier signal lost while receiving
0: Off
1: On
3
Not used
4
Maximum allowable frame interval
during image data reception.
0: 5 s 1: 13 s
5
Not used
6
Reconstruction time for the first line in
receive mode
0: 6 s 1: 12 s
7
Not used
G3 Switch 0B Not used (do not change the settings).
D255/D256 FAX OPTION
Value (ms)
Try a longer setting if error code 0-22 is
frequent.
200
400
800
Not used
This switch setting determines if
high-speed receiving ends if the carrier
signal is lost when receiving during
non-ECM mode
Do not change the settings
This bit set the maximum interval
between EOL (end-of-line) signals and
the maximum interval between ECM
frames from the other end.
Try using a longer setting if error code
0-21 is frequent.
Do not change the settings.
When the sending terminal is controlled
by a computer, there may be a delay in
receiving page data after the local
machine accepts set-up data and sends
CFR. This is outside the T.30
recommendation. But, if this delay
occurs, set this bit to 1 to give the
sending machine more time to send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line
should come within 5 s of CFR.
Do not change the settings.