Service Call 501-582
SC No.
Type
SC No.
Type
SC581-00
C
D255/D256/M281/M282
Error Name/Error Condition/Major Cause/Solution
Connector pin defective
If the I/F connector pins of the fuser unit and the main unit
are deformed owing to foreign materials, replace the
connectors or the units including the connectors.
Triac defective
Disconnect the power cord and check that the resistance
between terminals T1 and T2 of the triac TRA31 and triac
TRA41 on the PSU are several Mega-Ohms and not
shorted. If failed, replace the PSU.
Fusing thermistor defective
Replace the fusing unit.
IOB defective
Replace the IOB.
Error Name/Error Condition/Major Cause/Solution
Temperature Sensor Disconnected Error
The average of the output from the temperature sensor is
1019 or more for 160 ms.
The average of the output from the temperature sensor is
930 or more for 5 seconds.
Temperature sensor defective
IOB defective