Fusing Thermistor (Center) Disconnected Error
Input from fusing thermistor (center) is 1019 or more (A/D value)
continuously for 4 seconds.
Connector pin defective
Triac defective
Fusing unit defective
Fusing thermistor connection PCB defective
IOB defective
Fusing thermistor (center) defective
Fusing thermostat defective
PSU defective
Connector pin defective
If the I/F connector pins of the fuser unit and the main unit
are deformed owing to foreign materials, replace the
connectors or the units including the connectors.
Triac defective
Disconnect the power cord and check that the resistance
between terminals T1 and T2 of the triac TRA31 and triac
TRA41 on the PSU are several Mega-Ohms and not
shorted. If failed, replace the PSU.