Code
44
The data to be overwritten
cannot be accessed when
controller-related programs
are downloaded.
49
Firmware updates are
currently prohibited.
50
The results of the electronic
authorization check have
rejected the update data.
57
@Remote is not connected at
the date/time reserved for
receiving the package
firmware update from the
*1
network.
58
Update cannot be done due to
a reception route problem.
59
HDD is not mounted.
60
HDD could not be used during
the package firmware update.
*1
61
The module ID for the
package firmware update is
*1
incorrect.
62
The configuration of the
package firmware update files
is incorrect.
SM
Contents
*1
*1
*1
5-13
Solutions
Switch the main power supply off and
on to try again.
Install the correct ROM update data in
the SD card.
Replace the controller board if the data
to be overwritten is contained on the
controller board.
The setting of Update Firmware in the
Administrator Tools has been set to
[Prohibit] by an administrator. Amend
the setting to [Do not Prohibit] and try
again.
Install the correct ROM update data in
the SD card.
Check the @Remote connection.
Check the @Remote connection.
Check the HDD connection.
Try again.
Replace the HDD if the download fails
again.
Prepare the correct package files.
Prepare the correct package files.