Service Call 501-582
SC No.
Type
SC520-01
D
SC No.
Type
SC520-02
D
D255/D256/M281/M282
Error Name/Error Condition/Major Cause/Solution
Main Motor Error 1
The main motor is not stabilized within 2 seconds after the motor
is activated.
Main motor defective
IOB defective
Main motor defective
1. Reconnect the following connector. Then perform a
conduction inspection. If there is no conduction, replace
the connector.
IOB – Main Motor connector
2. Replace the main motor.
IOB defective
1. Update the engine software to the latest version.
2. Replace the IOB.
Error Name/Error Condition/Major Cause/Solution
Main Motor Error 2
After the main motor is stabilized, the stable OFF signal is
detected for 2 seconds consecutively.
Main motor defective
IOB defective
Main motor defective
1. Check if the gears rotate smoothly. If any gears are
damaged, replace them.
2. Reconnect the following connector. Then perform a
conduction inspection. If there is no conduction, replace
the connector.
IOB – Main Motor connector
3. Replace the main motor.
IOB defective
1. Update the engine software to the latest version.
2. Replace the IOB.