Avaya Definity SI Maintenance Manual page 41

Table of Contents

Advertisement

How to use the Maintenance book
14. Look in
"FAIL" in the Test Result column. See the Description/Recommendation
information.
Table 1-3. TEST #35 Port Diagnostic Test
Error
Test
Code
Result
61472
FAIL
15. Perform both steps in the Description/Recommendation column.
16. Test the port (test port 01C1008 long and press
recommendations are exhausted.
17. If all tests pass, wait approximately 3-5 minutes for the Alarm and Error
logs to clear.
18. Type display alarms and press
19. Check that the DID-TRK alarm does not appear in the log.
Field descriptions
Error type
Error List
Interval
From:/To:
Cabinet
Port Network
Board Number
Port
Category
555-233-123
Table 1-3
for Test #35, then "61472" in the Error Code column, and
Description/Recommendation
Battery feed test failed. A problem with the incoming CO line was detected.
1. Check the incoming CO line for proper operation. If warranted,
refer the problem to the CO.
2. If the CO line checks out Ok, the failure must be on the DID
port. Replace the circuit pack.
Enter error type, or blank
active-alarms, errors, or cleared-errors
h(our), d(ay), w(eek), m(onth), a(ll)
Specify time interval by date and time
Enter cabinet number (1 - 44)
Enter port network number (1 - 44)
Enter 5-character board number in UUCSS format:
cabinet (1-44), carrier (A-E), slot (0-20)
Enter 7-character port address in UUCSSss format:
cabinet (1-44), carrier (A-E), slot (0-20), circuit (01-31)
Enter category name (choose 1 from the list below:
adm-conn
announce
detector
dup-spe
generatr
inads-link
) after all of the
Enter
twice.
Enter
bri/asai
cdr
data-mod
environ
exp-intf
ext-dev
infc
maint
mass-st
Issue 4 May 2002
1-5

Advertisement