Dc Controller Pcb; Tpm Pcb; Flash Pcb - Canon imageRUNNER ADVANCE C3325 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C3325 Series:
Table of Contents

Advertisement

5
Adjustment■>■Actions■after■Replacement■>■TPM■PCB
*1:■Remote■UI■>■Settings/Registration■>■Management■Settings■>■Data■Management■>■Import■
or■Export
*2:■Remote■UI■>■Settings/Registration■>■Management■Settings■>■User■Management■>■
Authentication■Management■>■User■Management■
*3:■Remote■UI■>■Quick■Menu■>■Export
*4:■Remote■UI■>■Settings/Registration■>■Management■Settings■>■Data■Management■>■Back■
Up■or■Restore
*5:■Remote■UI■>■Service■Management■Service
*6:■Remote■UI■>■Settings/Registration■>■Management■Settings■>■Device■Management■>■Save■
Audit■Log
Audit■log■that■was■exported■cannot■be■put■back■to■the■device■from■which■the■log■was■
exported.
*7:■Settings/Registration■>■Management■Settings■>■Data■Management■>■TPM■Settings
*8:■Download■mode■>■[5]:■Backup/Restore■>■[3]■:■MEAP■Backup■>■Meapback.bin
Backup■is■possible■using■SST■or■USB■memory
The■data■saved■using■a■MEAP■application■can■be■backed■up■only■when■the■MEAP■
application■has■a■backup■function.
*9:■Backup■Method■using■DCM
When■You■set■it■in■COPIER>■OPTION>■USER>■SMD-EXPT>■ON,■a■backup/restore■is■
possible■in■Service■Mode■Settings■from■the■Remote■UI.There■is■a■backup■button■on■the■
TOP■page■of■the■service■mode.
1.■Remote■UI■>■Settings/Registration■>■Management■Settings■>■Data■Management■>■
Import/Export■All
2.■Remote■UI■>■Settings/Registration■>■Management■Settings■>■Data■Management■>■
Import/Export
3.■Service■mode■top■screen■>■BACKUP
Service■mode■setting■values■only■can■be■backed■up■and■restored.
4.■Web■Service
*10:■The■setting■value■that■was■set■when■the■main■power■was■turned■OFF■the■last■time■is■
automatically■backed■up■to■the■Flash■PCB.
When■a■HDD■is■replaced■with■a■new■one,■the■setting■value■is■automatically■inherited■from■the■
Flash■PCB■at■the■time■of■HDD■formatting.■(This■function■can■be■used■from■MN-CON■V06.xx)
5
Adjustment■>■Actions■after■Replacement■>■TPM■PCB
Main■controller■PCB
Item
Replacing■method "Removing■the■Main■Controller■PCB"(page■4-49).
Operation■at■
Replace■parts■from■an■old■PCB■to■a■new■PCB.
Replacement
•■ Memorey■PCB
•■ FLASH■PCB
•■ TPM■PCB
Prohibited■
Do■not■transfer■the■following■parts■to■another■model■(which■has■a■different■serial■
Operation
number).
If■you■fail■to■do■so,■the■Main■Body■does■not■activate■normally■and■this■might■
cause■to■fail■the■restoration.
•■ Main■Controller■PCB
•■ Memorey■PCB
•■ FLASH■PCB
•■ TPM■PCB
DC■controller■PCB
Item
Replacing■method "Removing■the■DC■Controller■PCB"(page■4-51).
Operation■at
1)■Backup■the■Service■Mode■data.
Replacement
(Lv.2)■COPIER■>■FUNCTION■>■SYSTEM■>■DSRAMBUP
After■"ACTIVE"■is■displayed■for■approx.■2■minutes,■"OK!"■is■displayed.
*:■If■necessary,output■the■servise■mode■setting■values■by■P-PRINT■before■
execution.
(Lv.1)■COPIER■>■FUNCTION■>■MISC-P■>■P-PRINT
2)■After■the■above■execution■is■completed,■turn■OFF■the■main■power■supply.
Prohibited
1)■Restore■of■the■Service■Mode■data.
Operation
(Lv.2)■COPIER>■FUNCTION>■SYSTEM>■DSRAMRES
"ACTIVE"■is■displayed■at■execution■and■then■"OK!"■is■displayed■about■2■
minutes■later.■Restoration■is■complete.
2)■If■uploading■of■backup■data■fails■before■replacement■due■to■the■damage■to■the■
DC■Controller■PCB,■enter■the■values■of■service■mode■items■recorded■on■the■
service■label■or■P-PRINT.
3)■Turn■OFF■and■then■ON■the■main■power■switch
TPM■PCB
Item
How■to■Replace
Refer■to■"Security■Function■(Encryption■Key,■Certificate■and■Protection■of
the■Parts
Password)"
5-7
Specification
T-5-5
Specification
T-5-6
Specification
T-5-7
5-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents