Canon imageRUNNER ADVANCE C3325 Series Service Manual page 661

Hide thumbs Also See for imageRUNNER ADVANCE C3325 Series:
Table of Contents

Advertisement

COPIER>ADJUST>FEED-ADJ
LP-DUP3
Adj pre-rgst arch amount: thin, 2-sided
Lv.1 Details
To adjust the arch amount before registration for thin paper fed in
2-sided mode.
As the value is changed by 1, the arch amount is changed by 0.1 mm.
+: Increase
-: Decrease
Use case
When an image on the 2nd side of thin paper fed in 2-sided mode is
skewed
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Display/adj/set range
-50 to 50
Unit
0.1 mm
Default value
0
LP-MULT3
Adj pre-rgst arch amount: thin, MP Tray
Lv.1 Details
To adjust the arch amount before registration for thin paper fed from
the Multi-purpose Tray.
As the value is changed by 1, the arch amount is changed by 0.1 mm.
+: Increase
-: Decrease
At first, change the value in increments of 10, and then make a fine
adjustment.
Use case
When an image on the 1st side of thin paper fed from the Multi-
purpose Tray is skewed
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Caution
If the value is too large, paper wrinkles may occur.
Display/adj/set range
-50 to 50
Unit
0.1 mm
Default value
0
8
Service Mode > COPIER > ADJUST > CST-ADJ
T-8-29
8
Service Mode > COPIER > ADJUST > CST-ADJ
■ CST-ADJ
COPIER>ADJUST>CST-ADJ
MF-MAX
Adj of Multi-purpose Tray maximum width
Lv.1 Details
To adjust the maximum width of the Multi-purpose Tray.
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
When registering a new value, execute COPIER> FUNCTION> CST>
MF-MAX.
Use case
• When replacing the DC Controller PCB/clearing RAM data
• When registering a new value
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
• After the setting value is changed, write the changed value in the
service label.
• Be sure to adjust MF-MIN together with this item.
Display/adj/set range
0 to 255
Default value
According to the setting at shipment
Related service mode
COPIER> FUNCTION> CST> MF-MAX
COPIER> ADJUST> CST-ADJ> MF-MIN
MF-MIN
Adj of Multi-purpose Tray minimum width
Lv.1 Details
To adjust the minimum width of the Multi-purpose Tray.
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
When registering a new value, execute COPIER> FUNCTION> CST>
MF-MIN.
Use case
• When replacing the DC Controller PCB/clearing RAM data
• When registering a new value
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
• After the setting value is changed, write the changed value in the
service label.
• Be sure to adjust MF-MAX together with this item.
Display/adj/set range
0 to 255
Default value
According to the setting at shipment
Related service mode
COPIER> FUNCTION> CST> MF-MIN
COPIER> ADJUST> CST-ADJ> MF-MAX
8-110
T-8-30
8-110

Hide quick links:

Advertisement

Table of Contents
loading