■ ENV-SET
COPIER > OPTION > ENV-SET
ENVP-INT
Temp&hmdy/Fix Film temp log get cycle
Lv.1 Details
To set the cycle to obtain log of the temperature and humidity inside
the machine and the surface temperature of the Fixing Film.
As the value is incremented by 1, the cycle is increased by 1 minute.
Collected log can be displayed in COPIER> DISPLAY> ENVRNT.
Use case
At problem analysis
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 480
Default value
60
Related service mode COPIER> DISPLAY> ENVRNT
AINR-TM
Set time not in use for drum idl rtn exe
Lv.2 Details
To set the time the machine is not in use that is the condition to
execute idle rotation of the drum.
When the machine is not used for more than the specified time, idle
rotation of the drum (60 seconds) is executed at warm-up rotation.
Decrease the value when uneven density occurs at certain intervals on
the image at the beginning of a workday after holidays (the beginning
of week is assumed).
When 0 is set, idle rotation of the drum is not executed.
Use case
When uneven density at intervals of the Primary Charging Roller or
Secondary Transfer Outer Roller circumference occurs on the image
printed at the beginning of a workday after holidays
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When idle rotation of the drum is executed, it takes long time for
startup than usual.
Display/adj/set range
0 to 60
0: OFF, 1 to 7: Not used, 8: 8 hours, ..., 60: 60 hours
Unit
1 hour
Default value
0
INTRTMPL
Set initial rotn extsn condtn: low temp
Lv.2 Details
To set temperature inside the machine and process speed that are the
conditions to extend the initial rotation time at low temperature.
Use case
When black lines in vertical scanning direction appear at approx. 30
mm from the image leading edge
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
FCOT becomes approx. 1 second longer.
Display/adj/set range
0 to 2
0: 18 deg C or lower, 1/2 speed
1: 18 deg C or lower, 1/1 speed, 1/2 speed
2: Whole temperature range, 1/1 speed, 1/2 speed
Default value
0
8
Service Mode > COPIER > OPTION > ENV-SET
8
Service Mode > COPIER > OPTION > ENV-SET
COPIER > OPTION > ENV-SET
INTRTMPH
Set initial rotn extsn condtn: high temp
Lv.2 Details
To set temperature inside the machine and process speed that are the
conditions to extend the initial rotation time at high temperature.
Use case
When uneven density/blur at intervals of drum circumference occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
FCOT becomes approx. 4 seconds longer.
Display/adj/set range
0 to 2
0: 40 deg C or higher, 1: Whole temperature range, 2: Disabled
Default value
0
LES-CNDS
Set of condensation prevention mode
Lv.2 Details
To set the mode to prevent condensation.
When 1 or 2 is set, idle rotation of the Reverse Roller is performed
even when paper is delivered to the First Delivery Tray in the case of
1-sided output.
In the case of 2-sided output, operation differs depending on whether
the 3 Way Unit is installed.
When the 3 Way Unit is installed, paper is always delivered via the
large path regardless of paper size.
When the 3 Way Unit is not installed, idle rotation of the Fixing Unit is
performed for the specified time before the start of a job.
Use case
- When condensation occurs
- When white lines appear on the 2nd side with 2-sided continuous
feeding
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
- Drive noise becomes approx. 0.6 to 1.4 dB louder due to idle rotation
of the Reverse Roller.
- When the 3 Way Unit is installed, productivity decreases.
- When the 3 Way Unit is not installed, FCOT becomes longer.
Display/adj/set range
0 to 2
- When the 3 Way Unit is installed:
0: Normal, 1, 2: Pass through the large path at 2-sided feed
- When the 3 Way Unit is not installed:
0: Normal, 1: 30 seconds, 2: 60 seconds
Default value
0