Canon imageRUNNER ADVANCE C3325 Series Service Manual page 707

Hide thumbs Also See for imageRUNNER ADVANCE C3325 Series:
Table of Contents

Advertisement

COPIER > OPTION > IMG-FIX
TMP-TB23
Set fixing control temp: plain, 1/2 SPD
Lv.1 Details
To set the offset of fixing control temperature for plain paper 1/2/3,
recycled paper 1/2/3, thin paper, colored paper, tracing paper, pre-
punched paper and bond paper at 1/2 speed.
As the value is changed by 1, the control temperature is changed by 5
deg C.
Increase the value when a fixing failure occurs, and decrease the value
when fixing offset occurs.
Use case
When a fixing failure/fixing offset occurs on plain paper, etc. at 1/2
speed
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
8
Service Mode > COPIER > OPTION > IMG-DEV
T-8-47
8
Service Mode > COPIER > OPTION > IMG-DEV
■ IMG-DEV
COPIER > OPTION > IMG-DEV
DRM-IDL
Set first idle rotation time in HH Env
Lv.1 Details
To set the idle rotation time to be performed at the beginning of a
workday in an HH (high temperature and high humidity) environment.
Use case
When coarseness occurs on the image at the beginning of a workday
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
When 1 is set, startup takes time.
Display/adj/set range
0 to 2
0: OFF, 1: ON (HH environment only), 2: ON (all environments)
Default value
0
AUTO-DH
Set Dmax/Dhalf ctrl exe cndtn: wrmup rtn
Lv.1 Details
To set the condition to additionally execute D-max/D-half control at
warm-up rotation after the machine is not used for 8 hours or more.
When 0 is set, additional execution of D-max/D-half control is not
performed.
When 1 is set, additional execution is performed only in an HH (high
temperature and high humidity) environment.
When 2 is set, additional execution is performed regardless of
environment.
When 3 is set, warm-up rotation is executed regardless of how long
the machine is not used and D-max/D-half control is additionally
executed regardless of environment.
Use case
When uneven density at intervals of the Primary Charging Roller or
Secondary Transfer Outer Roller circumference or density variation
occurs on approx. 10 images printed immediately after the machine
is not used for 8 hours or more
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When D-max/D-half control is executed at warm-up rotation, it takes
longer time for startup than usual.
Display/adj/set range
0 to 3
0: Not executed additionally
1: Executed additionally in an HH environment (after the machine is
not used for 8 hours)
2: Executed additionally in all environments (after the machine is not
used for 8 hours)
3: Executed additionally in all environments (not depending on how
long the machine is not used)
Default value
1
Supplement/memo
Warm-up rotation is executed automatically at power-on and
recovery from sleep mode when the machine is not used for 8 hours
or more regardless of environment.
8-156
8-156