COPIER>FUNCTION>PART-CHK
MTR-ON
Operation check of motor
Lv.1 Details
To start operation check of the motor specified by MTR.
When MTR is 8, 12, 13 or 19, motor is driven for 10 seconds and is
automatically stopped.
In other cases, motor is stopped after 30 seconds.
Use case
When replacing the motor/checking the operation
Adj/set/operate method Select the item, and then press OK key.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Required time
30 sec/10 sec
Related service mode
COPIER> FUNCTION> PART-CHK> MTR
SL
Specification of operation solenoid
Lv.1 Details
To specify the solenoid to operate.
Use case
When replacing the solenoid/checking the operation
Adj/set/operate method Enter the value, and then press OK key.
Display/adj/set range
1 to 2
1: Registration Shutter Solenoid (SL02)
2: Duplex Reverse Solenoid (SL06)
Default value
1
Related service mode
COPIER> FUNCTION> PART-CHK> SL-ON
SL-ON
Operation check of solenoid
Lv.1 Details
To start operation check of the solenoid specified by SL.
The operation stops after "ON for 2 sec" => "OFF for 5 sec" => "ON
for 2 sec" => "OFF for 5 sec" => "ON for 2 sec".
Use case
When replacing the solenoid/checking the operation
Adj/set/operate method Select the item, and then press OK key.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Required time
1 min
Related service mode
COPIER> FUNCTION> PART-CHK> SL
8
Service Mode > COPIER > FUNCTION > CLEAR
T-8-39
8
Service Mode > COPIER > FUNCTION > CLEAR
■ CLEAR
COPIER>FUNCTION>CLEAR
ERR
Clearing of error code
Lv.1 Details
To clear error codes (E000, E001, E002, E003, E717, and E719).
Use case
At error occurrence
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
DC-CON
Clearing of DC Controller PCB RAM data
Lv.1 Details
To clear the RAM data of the DC Controller PCB.
Use case
When clearing RAM data of the DC Controller PCB
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- Output the service mode setting values by P-PRINT before execution.
After execution, enter necessary setting value.
- The RAM data is cleared after the main power switch is turned OFF/
ON.
Related service mode COPIER> FUNCTION> MISC-P> P-PRINT
R-CON
RAM clear of Reader Unit
Lv.1 Details
To clear the RAM data of the Reader Unit.
Use case
When clearing the RAM data of the Reader Unit
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- Before execution of this item, be sure to output the service mode
setting values by P-PRINT. After execution, enter necessary setting
values.
- The RAM data is cleared after the main power switch is turned OFF/
ON.
Related service mode COPIER> FUNCTION> MISC-P> P-PRINT
JAM-HIST
Clearing of jam log
Lv.1 Details
To clear the jam logs.
Use case
When clearing the jam logs
Adj/set/operate method Select the item, and then press OK key.
Related service mode COPIER> DISPLAY> JAM
ERR-HIST
Clearing of error log
Lv.1 Details
To clear the error logs.
Use case
When clearing the error logs
Adj/set/operate method Select the item, and then press OK key.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Related service mode COPIER> DISPLAY> ERR
PWD-CLR
Clear of system administrator password
Lv.1 Details
To clear the password of the system administrator set in Settings/
Registration menu.
Use case
When clearing the password of the system administrator
Adj/set/operate method Select the item, and then press OK key.
8-123