005-946 SS-Size Mismatch Jam On No Mix-Size (Cont) RAP

BSD-ON:
BSD 5.2 - Document Size Sensing (1 of 2)
BSD-ON:
BSD 5.4 - Document Feed (1 of 2)
BSD-ON:
BSD 5.5 - Document Feed (2 of 2)
BSD-ON:
BSD 5.6 - Document Scan and Invert
In No Mix mode, it was detected that a document with a different size in Slow Scan (SS) direc-
tion was transported from the DADF. (If paper was not fed, 005-946 is displayed. If paper was
fed, 005-948 is displayed.)
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
Check the sw version of the controller sw - update if required
Document Tray Size Sensor 1/2:
Component Control
Check the circuit between the Document Tray Size Sensor 1/2 and the DADF PWB.
DADF Feed Out Sensor:
Component Control
DADF Registration Sensor:
Component Control
DADF APS Sensors 1-3:
Component Control
Check the circuit between the DADF APS Sensors 1-3 and the DADF PWB.
If no problems are found, replace the DADF PWB
Change the system data 700-530 to "0" and disable the automatic startup boot operation
at System Fail (make sure to reset to 1 when complete
Initial Issue
WorkCentre 5335 Family Service Documentation
[005-221/222]
(PL
51.10)
[005-205]
(PL
51.16)
[005-110]
(PL
51.17)
[005-218/219/220]
(PL
51.17)
(PL
51.2).
BUS Updated 12/2011
005-947 FS-Size Mismatch Jam On No Mix-Size or SS Mix-
Size RAP
BSD-ON:
BSD 5.3 Document Size Sensing (2 of 2)
BSD-ON:
BSD 5.4 - Document Feed (1 of 2)
In No Mix or Slow Scan (SS) Mixed mode, it was detected that a document with a different size
in Fast Scan (FS) direction was transported from the DADF. (If paper was not fed, 005-945 is
displayed. If paper was fed, 005-947 is displayed.)
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
Check the sw version of the controller sw - update if required
Check that the DADF Tray Set Guide operates normally.
DADF Tray Set Guide Sensors 1-3:
Check the circuit between the DADF Tray Set Guide Sensors 1-3 and the DADF PWB
DADF APS Sensors 1-3:
Component Control
Check the circuit between the DADF APS Sensors 1-3 and the DADF PWB.
If no problems are found, replace the DADF PWB
Change the system data 700-530 to "0" and disable the automatic startup boot operation
at System Fail (make sure to reset to 1 when complete
07/2011
2-81
Component Control
[005-215/216/217]
(PL
[005-218/219/220]
(PL
51.17)
(PL
51.2).
Status Indicator RAPs
005-946, 005-947
51.10)