005-132 DADF Invert Sensor On Jam RAP
BSD-ON:
BSD 5.6 - Document Scan and Invert
After the Read Speed Control operation started (DADF Registration Motor On (CCW)), the
DADF Invert Sensor did not turn ON within the specified time.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
Transportation failure due to foreign substance in the document path
•
The surface of the roll for foreign substance
•
The surface of the roll for wear
•
Check the sw version of the controller sw - update if required.
•
DADF Registration Motor:
Component Control
•
Check the circuit between the DADF Inverter Sensor and the DADF PWB
•
DADF Invert Sensor:
Component Control
•
DADF PWB failure.
(PL
51.2)
Initial Issue
WorkCentre 5335 Family Service Documentation
[005-033]
(PL
51.5)
[005-211]
(PL
51.9)
BUS Updated 12/2011
005-134 DADF Inverter Sensor Off Jam (During Invert) RAP
BSD-ON:
BSD 5.6 - Document Scan and Invert
•
After the DADF Registration Sensor turned OFF at Invert of the last document, the DADF
Inverter Sensor did not turn OFF within the specified time.
•
During the Invert where there is a next document, after the Read Speed Control operation
started (DADF Registration Motor On (CCW)), the DADF Inverter Sensor did not turn OFF
within the specified time.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
Transportation failure due to foreign substance in the document path
•
The surface of the roll for foreign substance
•
The surface of the roll for wear
•
Check the sw version of the controller sw - update if required.
•
DADF Registration Motor:
Component Control
•
Check the circuit between the DADF Registration Sensor and the DADF PWB
•
Check the circuit between the DADF Inverter Sensor and the DADF PWB
•
DADF Registration Sensor:
Component Control
•
DADF Invert Sensor:
Component Control
•
DADF PWB failure.
(PL
51.2)
07/2011
2-67
[005-033]
(PL
51.5)
[005-110]
(PL
51.17)
[005-211]
(PL
51.9)
Status Indicator RAPs