Toyota 2GR-FE Manual page 353

Table of Contents

Advertisement

17
CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)
Wire Harness Side:
Heated Oxygen Sensor Connector
HT1B
C52
Bank 1
OX1B
HT2B
C51
Bank 2
OX2B
C55
ECM Connector
EX2B
HT1B
HT2B
EX1B
OX2B
OX1B
2GR-FE ENGINE CONTROL SYSTEM – SFI SYSTEM
(a) Disconnect the C52 oxygen sensor connector (Bank 1
Sensor 2) or C51 oxygen sensor connector (Bank 2
sensor 2).
(b) Turn the ignition switch on (IG).
(c) Measure the voltage according to the value(s) in the
table below.
Standard voltage
+B
E2
(d) Turn the engine switch off.
(e) Disconnect the C55 ECM connector.
(f)
Measure the resistance according to the value(s) in the
+B
table below.
Standard resistance (Check for open)
E2
Standard resistance (Check for short)
HT1B (C52-1) or HT1B (C55-48) - Body ground
OX1B (C52-3) or OX1B (C55-88) - Body ground
E2 (C52-4) or EX1B (C55-65) - Body ground
HT2B (C51-1) or HT2B (C55-47) - Body ground
OX2B (C51-3) or OX2B (C55-87) - Body ground
A137615E05
E2 (C51-4) or EX2B (C55-64) - Body ground
(g) Reconnect the HO2 sensor connector.
(h) Reconnect the ECM connector.
Terminal Connection
+B (C52-2) - Body ground
+B (C51-2) - Body ground
Terminal Connection
HT1B (C52-1) - HT1B (C55-48)
OX1B (C52-3) - OX1B (C55-88)
E2 (C52-4) - EX1B (C55-65)
HT2B (C51-1) - HT2B (C55-47)
OX2B (C51-3) - OX2B (C55-87)
E2 (C51-4) - EX2B (C55-64)
Terminal Connection
ES–197
Specified Condition
9 to 14 V
9 to 14 V
ES
Specified Condition
Below 1 Ω
Below 1 Ω
Below 1 Ω
Below 1 Ω
Below 1 Ω
Below 1 Ω
Specified Condition
10 kΩ or higher
10 kΩ or higher
10 kΩ or higher
10 kΩ or higher
10 kΩ or higher
10 kΩ or higher

Hide quick links: