CO–10
CO
2GR-FE COOLING – WATER PUMP
A128122
Water Hose
Water Inlet Housing
A133375E01
SST
A128112E01
A135522
• Be sure to replace 2 bolts C with new ones or
reuse them after applying adhesive 1344.
Adhesive:
Toyota Genuine Adhesive 1344, Three Bond
1344 or Equivalent
2.
INSTALL WATER INLET HOUSING
(a) Install a new water inlet housing No. 1 gasket and
water outlet pipe O-ring.
(b) Install the water inlet housing with the 2 bolts and
nut.
Torque: 10 N*m (102 kgf*cm, 7 ft.*lbf)
NOTICE:
Be careful not to allow the O-ring to get caught
between the parts.
(c) Connect the water hose.
3.
INSTALL WATER PUMP PULLEY
(a) Temporarily install the water pump pulley with the 4
bolts.
(b) Using SST, hold the water pump pulley.
SST
09960-10010 (09962-01000, 09963-00700)
(c) Tighten the 4 bolts.
Torque: 21 N*m (214 kgf*cm, 15 ft.*lbf)
4.
INSTALL V-RIBBED BELT TENSIONER ASSEMBLY
(a) Install the V-ribbed belt tensioner assembly with the
5 bolts.
Torque: 43 N*m (438 kgf*cm, 32 ft.*lbf)