Verify Operation
Using the Maintenance Web Interface:
1
Under Server click Process Status.
2
Select "Summary and Display once" and click View to access the View Process Status Results
page.
3
Make sure everything except
show
65/65 UP
The number of processes (67/67) may vary depending on the configuration. For a normal state,
the second number should not be greater than the first number. For example, the numbers 66/67
UP would indicate that a process did not come up and should be investigated before proceeding.
4
Using a telephone, make test calls to verify that call processing is working.
Next Steps
This completes the S8300 upgrade process for upgrading from a 1.x software release to release 2.0. You
now must upgrade the G700 and media module firmware and then install and restart IA770, if installed
on the S8300.
Installation and Upgrades for G700 and S8300
December 2003
Upgrading an Existing G700 with an S8300 — R1.x to R2.0
,
, and
ENV
arbiter
or, if IA770 is installed,
67/67 UP
shows UP.
dupmgr
Communication Manger
.
5
Upgrade the S8300
should
249