Reported Event
Synchronization is
stopped
Synchronization is
aborted due to an internal
error.
Synchronization is
queued
Synchronization is
stopped internally
System (VessRAID)
The system is started
The system is stopped
Transition
Transition is started
Transition is completed
Transition is paused
Transition is resumed
Transition is stopped
Transition was switched
to rebuild
Watermark
Migration has detected/
cleared stale NV
Watermark
Array was incomplete due
to missing NV Watermark
Synchronization stopped because of user
intervention, schedule or the logical drive was deleted
or went critical or offline.
System resources are low. Reduce system load or
restart the VessRAID. See page 134 (WebPAM
PROe) or page 288 (CLU).
Synchronization is already running on another logical
drive in the same array.
Synchronization stopped because the disk array was
deleted or removed.
The VessRAID has been started.
The VessRAID was shut down.
Result of settings or user action. Normal.
Normal.
Transition paused because of user intervention,
schedule or a higher priority background activity.
Transition has resumed again after a pause.
Transition stopped because of user intervention or
the logical drive was deleted.
Transition changed to rebuild because the logical
drive went critical.
Watermarks are progress markers left as the result of
interrupted RAID migrations. If the watermark was
cleared, migration should finish.
RAID migration was interrupted by a shutdown.
If array is online, try migration again. See page 162
(WebPAM PROe) or page 237 (CLU).
If array is offline, delete and recreate array. See
page 158 and page 153 (WebPAM PROe) or
page 234 and page 230 (CLU).
393
Chapter 10: Troubleshooting
Corrective Action