The Transition feature enables you to specify "permanent" spare drives for your
VessRAID subsystem. Transition is the process of replacing a revertible spare
drive that is currently part of a disk array with an unconfigured physical drive or a
non-revertible spare. The revertible spare drive returns to its original status.
Transition happens automatically when the following sequence of events takes
place:
You create a revertible spare drive.
See page 176 (WebPAM PROe) or page 241 (CLU).
A physical drive assigned to your disk array fails and the array goes critical
or degraded.
VessRAID automatically rebuilds your array to the revertible spare drive and
the array becomes functional again.
You replace the failed physical drive with a new physical drive of equal or
greater capacity.
VessRAID automatically transitions (moves) the data from the revertible
spare to the new physical drive.
The new physical drive becomes part of the array and the revertible spare
drive returns to its original spare status.
Transition happens manually when you specify a different unconfigured physical
drive to transition (move) the data from the revertible spare drive.
See the example below.
VessRAID supports disk drive hot-swapping. To avoid hand
contact with an electrical hazard, do not remove more than one
drive carrier a time.
Caution