3.
Click the Software Management
4.
Click the Firmware Update tab.
5.
Do one of the following actions:
•
Click the Download Flash File from Local File through HTTP option,
then click the Next button.
•
From the Firmware Update tab dropdown menu, choose Download from
Local File.
6.
Enter the filename of the Firmware Update file in the field provided.
Or, click the Browse... button and choose the Firmware Update file in the
Open dialog box.
7.
Click the Submit button.
8.
When the download is completed, click the Next button.
A popup message appears to warn you not to reboot the VessRAID during
the firmware update procedure.
9.
In the popup message, click the OK button.
The update progress displays. Then a popup message appears to tell you to
reboot the VessRAID.
10. In the popup message, click the OK button.
11. Restart the VessRAID. See "Restarting the Subsystem" on page 315.
Restarting the Subsystem
To restart the VessRAID subsystem:
1.
Click the Subsystem
2.
Click the Administrative Tools
3.
Click the Shutdown link in Management View.
After you click the Submit button, if WebPAM PROe displays this
message: error transferring image, you entered an incorrect file
name or an incorrect location. Check the information and try
again.
Do not restart the VessRAID during a firmware upgrade
procedure. Wait until the upgrade is done and you are prompted to
restart.
icon in Tree View.
icon.
Note
Warning
icon.
315
Chapter 8: Maintenance