Making Netsend Settings - Promise Technology 1000f series Product Manual

Fc, iscsi, sas external disk array subsystems
Hide thumbs Also See for 1000f series:
Table of Contents

Advertisement

VessRAID 1000f, 1000i, 1000s Product Manual
4.
Click the Submit button.
5.
Click OK in the confirmation box.
Deleting Trap Sinks
To delete a trap sink:
1.
Highlight the trap sink you want to delete from the list.
2.
Click the Delete button to remove the trap sink from the list.
3.
Click the Submit button.
4.
Click OK in the confirmation box.
Changing the Startup Setting
1.
Under Startup Type:
Click the Automatic option to start the service automatically during
system startup. Recommended.
Click the Manual option to start the service manually (the service does
not start during system startup).
2.
Click the Submit button.
Stopping SNMP service
To stop the SNMP service:
1.
Click the Stop button.
2.
Click OK in the confirmation box.
Starting or Restarting SNMP service
To start or restart the SNMP service, click the Start or Restart button.

Making Netsend Settings

VessRAID's Netsend service sends VessRAID subsystem events in the form of
text messages to your Host PC and other networked PCs. This service is
normally Stopped and set to Manual start. See "Netsend Requirements" on
page 125.
To change the Netsend settings:
1.
Click the Subsystem
2.
Click the Administrative Tools
3.
Click the Netsend link.
4.
Click the Start button to start the Netsend service.
5.
Click the Submit button.
icon in Tree View.
icon.
124