Sas Jbod Expansion - Promise Technology 1000f series Product Manual

Fc, iscsi, sas external disk array subsystems
Hide thumbs Also See for 1000f series:
Table of Contents

Advertisement

VessRAID 1000f, 1000i, 1000s Series Product Manual

SAS JBOD Expansion

This arrangement requires:
One (1) or more VessJBOD expansion units
One (1) SFF-8088 to SFF-8088 SAS cable for each VessJBOD expansion
unit
Configuring the Data Path
All 16-bay and 12-bay VessRAID subsystems have one (1) SFF-8088 SAS
Expansion Port connector.
To expand the data path:
1.
Attach one end of a SFF-8088 to SFF-8088 SAS cable to the SAS
Expansion Port on the VessRAID subsystem.
See page 33, Figure 17.
2.
Attach the other end of the SFF-8088 to SFF-8088 SAS cable to the SAS IN
Port on the VessJBOD expansion units.
If you have another VessJBOD expansion unit, attach one end of the SFF-
8088 to SFF-8088 SAS cable to the SAS OUT Port of the first VessJBOD to
the SAS IN Port of the second VessJBOD.
Configuring a Management Path
The VessRAID controller manages the VessJBOD expansion unit. No additional
management connections are required for JBOD expansion.
VessJBOD expansion units have one SAS IN port and one SAS
OUT port. If you connect them incorrectly, the VessRAID does not
recognize the VessJBOD expansion units.
For more information, see the VessJBOD Product Manual on the
CD that came with the VessJBOD expansion unit.
Important