Rebuild Operation - Promise Technology 1000f series Product Manual

Fc, iscsi, sas external disk array subsystems
Hide thumbs Also See for 1000f series:
Table of Contents

Advertisement

VessRAID 1000f, 1000i, 1000s Series Product Manual
To enable Automatic Rebuild, see "Making Background Activity Settings" on
page 71 (WebPAM PROe) or page 264 (CLU).
To set Hot Spare Policy, see "Making Spare Drive Settings" on page 177
(WebPAM PROe) or page 242 (CLU)

Rebuild Operation

During rebuild:
The alarm sounds a single short beep, repeated.
No warning icon displays over the Disk Array or Logical Drive in the Tree.
Management View reports the Disk Array's Operational Status as OK,
Rebuilding.
The drive carrier holding the rebuilding physical drive displays a green
Activity (lower) LED while the Status (upper) LED flashes green once per
second.
Figure 17.VessRAID disk drive carrier LEDs
During rebuilding, you can still read and write data to the logical drive. However,
fault tolerance is lost until the Disk Array returns to OK (not-rebuilding) status.
After a successful rebuild:
The alarm is silent
The Disk Array's Operational Status as OK
The rebuilt disk drive Status LED displays steady green
If your replacement disk drive was formerly part of a different disk
array or logical drive, you must clear the configuration data on the
replacement drive before you use it.
See page 147 (WebPAM PROe) or page 227 (CLU).
.
Important
396