VessRAID 1000f, 1000i, 1000s Product Manual
RAID 50
A RAID 50 Source logical drive can migrate to the following Target logical drives:
Target
RAID 0
RAID 1E
RAID 3
RAID 5
RAID 6
RAID 10
RAID 30
RAID 50
RAID 60
RAID 60
A RAID 60 Source logical drive can migrate to the following Target logical drives:
Target
RAID 6
RAID 60
None.
None.
32 physical drives maximum.
RAID 50 must have less than 32 physical drives.
32 physical drives maximum.
RAID 50 must have less than 32 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
Even number of physical drives.
6 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
Add physical drives. 32 per axle maximum.
8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
16 physical drives maximum.
RAID 60 must have less than 32 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
Add physical drives. 32 per axle maximum.
Requirements
Requirements
358