Promise Technology 1000f series Product Manual page 408

Fc, iscsi, sas external disk array subsystems
Hide thumbs Also See for 1000f series:
Table of Contents

Advertisement

VessRAID 1000f, 1000i, 1000s Series Product Manual
Reported Event
PDM is stopped internally The destination drive was removed or used for a
Physical Disk
Physical disk is marked
online
Physical disk is marked
online
Physical disk is marked
as dead.
Physical disk is marked
as dead after it was
removed and reinserted
by the user.
Physical disk has been
reset
Physical disk assigned as
global spare
Physical disk is no longer
assigned as global spare
Physical disk assigned as
dedicated spare
Physical disk is no longer
assigned as dedicated
spare
Physical disk has been
inserted
Physical disk has been
removed
Bad sector is found on
physical disk
Error is detected in remap
sectors
Command times out on
physical drive
rebuild.
Disk drive restored to normal operation.
Disk drive removed from service due to errors. If
necessary, try to force the disk online. See page 147
(WebPAM PROe) or page 228 (CLU).
Disk drive failure. Replace the disk drive.
Try forcing the disk online. See page 147 (WebPAM
PROe) or page 228 (CLU)
Disk drive reset after error and should function
normally.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
Result of settings or user action. Normal.
A disk drive has been inserted into the VessRAID
subsystem.
A disk drive has been removed from the VessRAID
subsystem.
Disk drive has a bad sector. The drive should remap
around the bad sector. If this message appears
repeatedly, replace the disk drive.
Disk drive has a bad remap sectors. If this message
appears repeatedly, replace the disk drive.
Disk drive not responding to commands. If this
message appears repeatedly, replace the disk drive.
388
Corrective Action

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000i series1000s series