Figure 3. VessRAID mounted in a rack with the available rails
Vertical Rack Post
Handles mount
outside the rack post
To install the VessRAID subsystem into a rack with the supplied mounting rails:
1.
Check the fit of the mounting rails in your rack system.
See page 16, Figure 4.
2.
Adjust the length of the mounting rails as needed.
The rear rail slides inside the front rail. The rail halves are riveted together
and use no adjustment screws.
3.
Attach the mounting rail assemblies to the outside of the rack posts, using
the attaching screws and flange nuts from your rack system.
Be sure the front rail support is on the bottom facing inward.
The alignment pins fit into the rack holes above and below the attaching
screws.
Use the attaching screws and flange nuts from your rack system. Tighten the
screws and flange nuts according to your rack system instructions.
4.
Place the VessRAID subsystem onto the rails.
5.
Secure the VessRAID subsystem to the rack.
One screw each side, in the upper hole only. Use the attaching screws and
flange nuts from your rack system. Tighten the screws and flange nuts
according to your rack system instructions.
Chapter 2: VessRAID Installation
VessRAID subsystem
Mounting rails mount
outside the rack post
15