Starting Up After Shutdown
To start the RAID subsystem:
1.
Manually turn on the power supply switches on the back of the subsystem.
If the switches are ON but the subsystem is OFF, turn the switches off and
on again.
On subsystems with redundant power supplies, if the power switches do not
respond, unplug the power cords and plug them back in. Try the power
switches again.
2.
Wait about two minutes.
3.
Open your browser and log into WebPAM PROe.
See "Logging into WebPAM PROe" on page 58.
If you cannot log in, wait 30 seconds and try again.
Monitoring the Startup
To monitor a startup, you must use the Command Line Interface (CLI) though a
serial connection to the VessRAID.
When the Login: prompt appears, the start up is finished.
If you have a JBOD expansion, always power on the JBOD
expansion units first. Then power on the RAID subsystem.
Chapter 4: Management with WebPAM PROe
Important