Setting Temperature Thresholds

To change temperature thresholds:
1.
From the Main Menu, highlight Subsystem Management and press Enter.
2.
Highlight Enclosure Management and press Enter.
3.
Highlight Enclosure Settings and press Enter.
4.
Highlight the Temperature Warning threshold you want to change.
5.
Press the backspace key to erase the current value.
6.
Type a new interval value in degrees C.
7.
Press Ctrl-A to save your settings.

Checking the Batteries

This feature enables you monitor and recondition the subsystem battery or
batteries.
1.
From the Main Menu, highlight Subsystem Management and press Enter.
2.
Highlight Enclosure Management and press Enter.
3.
Highlight Batteries and press Enter.
4.
Highlight the battery you want to monitor and press Enter.
Battery Notes
Each battery works with a controller. If the battery is present in the subsystem but
the corresponding controller is not present, the battery will not appear in the
interface.
If a battery does not reflect normal conditions and it is not currently under
reconditioning, run the Recondition function before you replace the battery. See
"Reconditioning a Battery" on page 224.
Reconditioning fully discharges, then fully recharges the battery. During
reconditioning, if the Adaptive Writeback Cache function is enabled, the controller
cache is set to Write Thru. After reconditioning, the cache is reset to Write Back.
See "Making Controller Settings" on page 217.
If a battery reaches the threshold temperature while charging or discharging, the
charge or discharge pauses and the blower runs at high speed until the battery
temperature falls below the threshold.
If the battery does not maintain normal values after a Recondition, replace the
battery. See "Replacing the Cache Battery" on page 324.
VessRAID automatically reconditions the battery every two months.
When you install a new battery, the cycle count shows 0. VessRAID automatically
runs a recondition on the battery to verify it. If you restart the subsystem or
Chapter 6: Management with the CLU