Event Notification Response

When you choose Event Notification, WebPAM PROe sends popup and/or email
messages regarding its status. The messages you see depend on your
notification selection and what is currently happening in the VessRAID. See
"Setting-up User Event Subscriptions" on page 79.
The table below cites:
Reported Events – Events that require you to take action
Corrective Actions – The action you should take in response to the event
A list of event categories is shown below.
Battery (page 381)
Blowers (page 382)
Cache (page 383)
Controller (page 383)
Disk Array (page 383)
Drive Interface Controller
(page 384)
Enclosure (page 384)
Event Log (page 384)
Host Interface Controller
(page 384)
Logical Drive (page 385)
Media Patrol (page 386)
Online Capacity Expansion
(page 387)
Reported Event
Battery
Battery temperature is
above the threshold
Battery temperature is
normal
Battery capacity is below
the threshold
Battery capacity is normal Normal.
PDM (page 387)
Physical Disk (page 388)
PSU (Power Supply Units)
(page 389)
RAID Level Migration (page 390)
Rebuild (page 390)
Redundancy Check (page 391)
Resource (page 392)
Spare Check (page 392)
Spare Drives (page 392)
SMART (page 392)
Synchronization (page 392)
System (VessRAID) (page 393)
Transition (page 393)
Watermark (page 393)
The battery is too hot. Verify proper airflow around
the through the VessRAID. If airflow is OK, replace
the battery. See page 324.
Normal.
Battery is drained. Run battery reconditioning. See
page 143 (WebPAM PROe) or page 224 (CLU).