Shutting Down the Subsystem
You can only do part of this function in WebPAM PROe. Additional action is
required, as described below.
To shutdown the subsystem:
1.
Click the Subsystem
2.
Click the Administrative Tools
3.
Click the Shutdown link in Management View.
A Shutdown or Restart tab appears.
4.
Choose Shutdown from the dropdown menu and click the Submit button.
5.
In the confirmation box, type the word confirm in the field provided.
6.
Click the OK button.
When the controller shuts down, your WebPAM PROe connection is lost.
7.
Wait for no less than two minutes.
8.
Manually turn off the power supply switch (both switches with redundant
power supplies) on the back of the subsystem.
Monitoring the Shutdown
To monitor a shutdown, you must use the Command Line Interface (CLI) though
a serial connection to the VessRAID.
Turn off both power supply switches when the following this message appears:
Shutdown complete. It is now safe to power off the subsystem.
Powering Off the Subsystem
This option enables you to start the VessRAID NAS from SmartNAVI.
The Wake on LAN option must be enabled. See "Making Management Port
Settings" on page 83.
If you have a JBOD expansion, always power off the RAID
subsystem first. Then power off the JBOD expansion units.
icon in Tree View.
After you power off the subsystem, wait at least 10 seconds before
you power on the subsystem again.
Chapter 4: Management with WebPAM PROe
Important
icon.
Caution
131