Advanced Mode
Advanced Mode enables you to perform the Simple Mode functions, plus:
•
View Enclosure – View overall enclosure status. Also view individual status
of temperature, fan, power supply, and voltage
•
Physical Drive Management – View PD ID, model, interface, capacity,
location (enclosure and slot number), configuration (array and sequence
number), firmware version, status; Locate physical drive
•
Logical Disk Management – View LD ID, capacity, RAID level, write cache,
stripe size, sector size, disk array ID, status; Locate logical drive
Limitations
The LCD panel does not perform the following functions:
•
Setting enclosure date and time
•
Clearing a Stale or PFA condition from a physical drive
•
Creating a revertible spare drive or a dedicated spare drive
•
Running background activity, such as Media Patrol, PDM, Rebuild, or RAID
level migration
•
Making FC, iSCSI, or SAS settings
•
Viewing event logs
•
Shutting down or restarting the VessRAID
Refer to "Chapter 4: Management with WebPAM PROe" on page 57 and
"Chapter 6: Management with the CLU" on page 207 when you need to perform
these functions.
Viewing Events
Each event has a severity level defined as:
•
Information – Information only, no action is required.
•
Warning – User can decide whether or not action is required.
•
Minor – Action is needed but the condition is not a serious at this time.
•
Major – Action is needed now
•
Critical – Action is needed now and the implications of the condition are
serious.
•
Fatal – Non-Recoverable error or failure has occurred.
•
None – Deactivates this event for notification purposes.
293
Perusing the Interface