Managing Ups Units; Viewing A List Of Ups Units - Promise Technology 1000f series Product Manual

Fc, iscsi, sas external disk array subsystems
Hide thumbs Also See for 1000f series:
Table of Contents

Advertisement

VessRAID 1000f, 1000i, 1000s Product Manual

Managing UPS Units

Uninterruptible Power Supply (UPS) Management includes the following
functions:
Viewing a List of UPS Units (below)
Making UPS Settings (page 271)
Viewing UPS Information (page 272)

Viewing a List of UPS Units

To view a list of UPS units supporting the VessRAID:
1.
From the Main Menu, highlight Additional Info and Management and press
Enter.
2.
Highlight UPS Management and press Enter.
Information in the UPS List includes:
UPS ID – Click the ID number to view the UPS Tab.
Operational Status – OK means Normal.
On AC means the UPS is connected to a viable external AC power
source.
On Battery means the external AC power source is offline and the UPS
is running on battery power.
Model Name or Number
Capacity – Backup capacity expressed as a percentage.
Loading – Actual output of UPS as a percentage of the rated output.
See the Note below.
Remaining Minutes – Number of minutes the UPS is expected to power
your system in the event of a power failure.
The maximum recommended Loading Ratio varies among models
of UPS units. The general range is 60% to 80%. If the reported
Loading Ratio exceeds the recommended value for your UPS unit:
Have fewer subsystems or peripherals connected to this UPS
unit.
Add more UPS units, or use a higher-capacity UPS unit, to
protect your RAID systems.
Note