Konica Minolta bizhub PRO C5500 Solution Manual page 50

Ssd support solutions
Hide thumbs Also See for bizhub PRO C5500:
Table of Contents

Advertisement

bizhub PRO C5500
a. If you upgrade a server from a previous release to Lotus® Domino 6, the LDAP service uses the LDAP anonymous access configuration from the previous
release. If you create or edit the domain Configuration Settings documents after updating the directory with the Lotus® Domino 6 PUBNAMES.NTF design,
the list of attributes allowed for anonymous access include the following attributes (attached - ldap1.pdf)not listed in the previous release:
b.The Allservers configuration doc will only affect the servers running LDAP. It will also allow the MFPs to access LDAP without using an authentication
account and password. This is the method that all users are using according to Lotus® Incident 1632724.
c. Please refer to the attached document for more detail.
d. To view the document(s), Microsoft® Word® or Word® Viewer must be installed. Word® Viewer 2003 (11.7MB) can be obtained free from Microsoft® at
the following URL; http://www.microsoft.com/downloads/details.aspx?DisplayLang=en&FamilyID=95e24c87-8732-48d5-8689-ab826e7b8fdf .
e. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Mark D'Attilio, Production Print/SSD
Solution ID
TAUS0703268EN*
Description
ISW error codes list.
Solution
ISWERROR CODES
Error Code
Description
Action
01
There is an error in the command to ISW processing unit.
Program is not executing normally. Restart from power ON and re-execute the ISW.
1F
A program error is detected.
Program is not executing normally. Restart from power ON and re-execute the ISW.
41
Input data format error
Check the ISW transfer data file.
42
Invalid machine name input data
Check the ISW transfer data file.
43
Invalid board name input data
Check the ISW transfer data file.
81
Input device error such as input timeout.
Copyright , Konica Minolta Business Solutions U.S.A., Inc.
50
Miscellaneous
Solution Usage
4
March 2010

Hide quick links:

Advertisement

Table of Contents
loading