SOLUTION: To allow printing with a key counter installed, perform the following:
1. Enter Service Mode.
2. Press Stop, 9.
3. Select Management Function.
4. Set Printer to Not Object.
5. Exit Service Mode.
SPECIAL NOTE : Solution contribution by David Aekus and Ed Bellone, Production Print/SSD
Solution ID
TAUS0800839EN*
Description
FS-503, "grayed out" during install. Unable to flash the finisher.
Solution
CAUSE: Failed Finisher Control Board.
SOLUTION: Replace the FNSCB (p/n 15AA -931 2F). Set dipswitch 2 on the FS-503 control PWB to ON.
SPECIAL NOTE : Solution contribution by Mike McCarthy, Production Print/SSD
Solution ID
TAUS0801345EN*
Description
Incorrect/poor color output. YMCK test print solid color and halftones look normal.
Solution
CAUSE: Dirty or failed gamma sensor. Gamma values on the adjustment list will be at a low value.
SOLUTION: Replace the color registration assembly (p/n A03UR79800).
SPECIAL NOTE : Solution contribution by Ed Bellone, Production Print/SSD
Solution ID
TAUS0801377EN*
Description
No warm up completion. Intermittent fuser abnormality code (C35xx - C39xx).
Solution
CAUSE:Fusing unit will no longer make a proper electrical connection because it has been improperly installed.The wiring connector on the fusing unit has
been damaged and the receiver wiringon the mainbody side of the connection has been damaged.
SOLUTION:Replace the following parts:
Fixing power source wiring/2 -p/n A03U N106 01
AC driving wire - p/n A03U N118 01
WARNING : When C35xx, C38xx or C39xx (fusing temperature related abnormality) occurs, be sure to repair/replacethefailed part generating the code
before setting the Service mode software DIPSW3-1 to 0. Ifsoftware DIPSW 3-1 is set to 0 without correcting the cause of the error, a fire mayoccur. Please
refer to attached procedure. To viewthe PDF, Adobe Reader® must be installed. Adobe Reader® can be downloaded for free from the Adobe® web site at:
http://www.adobe.com/products/acrobat/readstep2.html .
SPECIAL NOTE : Solution contribution by Greg Lantowski, Production Print/SSD
Solution ID
TAUS0801569EN*
Description
FS-607, the trailing 1.5 inch of center folded Letter R paper is folded. Tabloid size is folded over at about 4 inches.
Solution
CAUSE: The tri-fold gate is stuck in the tri-fold position.
SOLUTION: Gravity will place this gate in the tri-fold position if either the gate arm is broken or the solenoid lever is broken or missing. Inspect and replace
the gate (p/n 13QJ44421) and the solenoid lever (p/n 13QJ44480) as needed.
SPECIAL NOTE : Solution contribution by Jim Behrends, Production Print/SSD