OfficeServ 7100
TECHNICAL MANUAL
MMC: 852
DESCRIPTION:
This MMC allows the assignment of system alarms to ring and display the alarms on
stations that have the Alarm Key assigned. The System Alarm Key is programmed
in Station Key Assignments (MMC 722). System Alarm key programming is tenant
wide (tenant 1 and 2). Alarms not programmed to report to the System Alarm key
will still be retained in the maintenance alarm buffer for Alarm Reporting (MMC 851).
The alarm buffer will hold up to 100 alarms on a First In - First Out (FIFO) basis.
Pressing the System Alarm key will silence the audible alarm until another alarm is
generated by the system. The specific fault alarm data can be displayed via MMC
851 System Alarm Reporting.
NOTE: Alarm Notification Off/On (0/1) determines if the alarm provides a visual and
audible notification to the System Alarm key station(s).
Pressing the System Alarm key and the release key will silence the audible
alarm only at the station that pressed the System Alarm key and the release
key. See alarm displays table for assignments.
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPEAKER
TRANSFER
ACTION
1. Press TRANSFER 852.
Display shows.
2. Enter desired Alarm Display number (eg. 16)
OR
Press the up and down keys to select
desired option and press the right soft key
and to advance the cursor.
3. To select if the alarm is active press 1 for
YES and 0 for NO. An entry will advance the
cursor to return to step 2.
SYSTEM ALARM ASSIGNMENTS
Used to scroll through system alarms.
Used to enter selections
Enter/leave option
Used to store data and move to next MMC
Enter/exit MMC
Home Page
PROGRAMMING
PART 2 APRIL 2007
DISPLAY
SYSTEM ALARM KEY
ALARM KEY/RING
SYSTEM ALARM KEY
NMS ALARM LEVEL
16:MJC05 AC:OFF
AC Pwr Loss