Download Print this page

Samsung OfficeServ 7100 Technical Manual page 472

Hide thumbs Also See for OfficeServ 7100:

Advertisement

OfficeServ 7100
TECHNICAL MANUAL
MMC: 851
DESCRIPTION:
This MMC is used to view, store, print or clear system alarms. There are two levels
of faults displayed via alarm code, major alarms and minor alarms. Major alarms
codes are usually service affecting and require a certified technician to determine
the fault. A minor alarm indicates a fault that may or may not be service affecting
and usually does not seriously degrade the systems operating capabilities. The
alarm buffer will hold up to 100 alarms on a first in - first out (FIFO) basis. Alarms will
provide a date and time stamp based on the system time. If applicable the hardware
cabinet, port, and/or slot will be displayed.
ALARM REPORTING OPTIONS (Select one of the options)
0
VIEW ALARM
1
OVERFLOW CONTROL
3
CLEAR ALARM BUF
4
PRINT ALARM BUF
ALARM CODE LOCATION DEFINITION (See Alarm Code Table)
C: Cabinet number
S: Slot number
P: Port number
Note: Cabinet, slot and port do not apply to all alarm codes
ALARM REPORTING
View alarm buffer
OVERWRITTEN − When buffer is full, the
oldest entry in buffer overwritten.
STOP RECORDING − When buffer is full, stop
recording alarms.
Clears alarm buffer.
Prints contents of alarm buffer to the assigned
alarm IO port.
Table of Contents
Home Page
PROGRAMMING
PART 2 APRIL 2007

Advertisement

loading