OfficeServ 7100
TECHNICAL MANUAL
MMC: 805
DESCRIPTION:
Allows the system administrator to set the base level of the TX volume on keysets
system wide. There are eight (8) levels those are able to be controled by the VOL
UP and DOWN key on keyset. And maximum controllable levels in the system are
ten (10). Keyset station users can vary eight levels. So this MMC gives the most
flexibility to the system administrator so he can classify any desired eight(8) levels
within eleven (11).
NOTE: This MMC should not be changed from the default levels without the
assistance of the STA technical support department
TX LEVEL
0
CONTROL
1
MISC TSW GAIN
TSW GAIN
2
CONTROL
0
DGP
1
DGP
2
DGP
3
DGP
0
4
DGP
5
DGP
6
DGP
7
DGP
1
0
SLT
1
SLT
2
SLT
3
SLT
4
SLT
Adjusts the transmitting sensitivity (Max. : 9)
INDEX : 0 1 2 3 4 5 6 7
LEVEL : 0 1 2 3 4 5 6 7
Adjusts the level of the internal music source of the MCP card or the
external music source of the MISC card.(0~7, higher numbers
mean lower levels)
Adjusts the tone sensitivity (As shown below, there are 25 types of
connections of the T-Switch that adjusts the tone sensitivity.
Connection between C.O. lines are only applicable when set as 0 in
Program 418.)
DGP
Adjusts sensitivity from digital phone Tx to digital phone Rx
SLT
Adjusts sensitivity from digital phone Tx to normal station Rx
ATRK
Adjusts sensitivity from digital phone Tx to analog C.O. Rx
DTRK
Adjusts sensitivity from digital phone Tx to digital C.O. Rx
ITP
Adjusts sensitivity from digital phone Tx to ITP Rx
VOIP
Adjusts sensitivity from digital phone Tx to VOIP C.O. Rx
SVMi
Adjusts sensitivity from digital phone Tx to SVM Rx
WLAN
Adjusts sensitivity from digital phone Tx to WLAN Rx
DGP
Adjusts sensitivity from normal station Tx to digital phone Rx
SLT
Adjusts sensitivity from normal station Tx to normal station Rx
ATRK
Adjusts sensitivity from normal station Tx to analog C.O. Rx
DTRK
Adjusts sensitivity from normal station Tx to digital C.O. Rx
ITP
Adjusts sensitivity from normal station Tx to ITP Rx
Home Page
PROGRAMMING
PART 2 APRIL 2007
LEVEL & GAIN