Download Print this page

Samsung OfficeServ 7100 Technical Manual page 477

Hide thumbs Also See for OfficeServ 7100:

Advertisement

OfficeServ 7100
TECHNICAL MANUAL
ALM
ALM
NO.
CODE
40
MJD09
41
MJD10
42
MJD11
43
MJD12
44
MJD13
45
MJD14
46
MJD15
47
MJD16
48
MJD17
49
MJD18
MMC: 852
ALARM
Bit Error Alarm
NTWRK Event
SPID Init Err
SPID Init Rec
LPBK Error
LPBK Recovery
BRI DL Unavail
BRI DL Recovered
RAM Error
T1 Restart
Home Page
PROGRAMMING
PART 2 APRIL 2007
DEFINITION
Alarm is activated when the when error
rate exceeds 1x10
-6
errors. Note: 1x10
is threshold for minor alarm, 1 x 10
threshold for major alarm errors on PRI
or BRI..
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
An Implausible event has occurred on
the PRI or BRI Network digital line.
Protocols do not match or subscriber ID
mismatch.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
The BRI received an error from the
network
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10),Channel(1 through 16)
The BRI has recovered from an error on
the network
Alarm Data = Cabinet, Slot Channel
C1,2
(S1 through 10),C (1 through 16)
Internal on demand loopback failed.
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10), (C1 through 24)
Internal on demand loopback test
passed.
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10), (C1 through 24)
A BRI data link is out of service.
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10), (C1 through 16)
A BRI data link is back in service.
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10), (C1 through 16)
An error has occurred in the T1/PRI or
BRI card RAM.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
The T1 card has restarted
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
Table of Contents