Issue 8.01
Conditions
Main software Version 5000 or higher and the Version 5.00 Main Version License
(0034) are required to support the NetLink Multi-SIP Carrier feature.
It is possible to set Register ID for trunks that belong to that specific system. For example, a
Register ID set in the Primary system cannot be assigned to a trunk in the Secondary
system. The allocation of the trunk and Register ID of Program14-12 must be in the same
system.
In order to use CPN in a secondary system, Program 51-19 must be turned on for those
extensions. Once enabled, CPN may be sent on a per station basis using Program 21-19.
Once NetLink is established, PCPro or WebPro must be used to change the system data
related to the SIP trunks.
Any SIP trunks that are built in a system before establishing NetLink will be deleted after
establishing NetLink.
SIP trunks are assigned in the order of system set up. System ID's are needed to assign
Program 10-40 data.
With Version 5000 (V5.00 or higher) software, the following programs no longer replicate
and can be set on a per system basis: 10-23, 10-37, 21-19, 84-13, and 84-14.
Each NetLink system can use either SIP trunks to a provider or SIP trunk TIE line mode but
not both.
Registered SIP trunks can be utilized by any system in the NetLink network as long as trunk
route programming allows it.
When a secondary system becomes the primary after fail over, the SIP trunks will work for
the effective license time.