SMDR requires a connection to the CD-CP00-US LAN, or a RS232 serial connection to a
CT(A)-R adaptor on a DTH/DTR style phone.
When using a CT(A)-R unit connected to a DTH/DTR style terminal for SMDR output:
SW1-1 and SW1-2 should be set to ON and SW1-3 ~SW1-8 set to OFF on the CT(A) unit
The CT(A)-R unit should be connected to the DTH/DTR terminal and connected to power
before the line cord is plugged in
DT300 and DT700 style terminals do not support a RS232 serial connection for SMDR
output.
If no answer is received, NO ANSWER is displayed regardless of the system programing
for the Caller ID display option.
The setting in Program 35-02-18 works regardless of the entry in Program 35-02-15 or
35-02-17.
When Program 35-02-18 is set to 1, the first and second lines are sometimes separated.
When the buffer is full, the overflowed data may not be shown.
The special characters used in the UNIVERGE SV8100 system cannot be output to the
SMDR – they are converted to (_).
To use the PBX Call Reporting option, program system for behind PBX operation.
Calls made from Virtual Extensions show up in SMDR as calls made from the physical
extension the VE resides on.