NEC Univerge SV8100 Features And Specifications Manual page 1531

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
16-01-03
Department Group Basic Data
Setup – Department Routing
When Busy (Auto Step Call)
16-01-04
Department Group Basic Data
Setup – Hunting Mode
16-01-09
Department Group Basic Data
Setup – Department Hunting No
Answer Time
16-01-10
Department Group Basic Data
Setup – Enhanced Hunt Type
16-02-01
Department Group Assignment
for Extensions
20-01-10
System Options – Trunk Guard
Timer
UCB (Unified Communications for Business)
Description/Comments
Set how the system routes an
Intercom call to a busy
Department Group member. The
caller can hear busy tone (0) or
overflow to the first available
Department Group member (1).
This option is for Intercom calls to
an extension, not a pilot number.
Needs to be set to circular.
Set the action taken when a call
reaches the last extension of the
department group.
Needs to be set to circular.
Set the time a call rings a
Department Group extension
before hunting occurs.
Set the type of hunting for each
Extension (Department) Group.
Needs to be set to Busy
Set up the Department Group
called by the pilot number and the
extension priority when a group is
called.
Call Pickup Groups are set up in
23-02.
Assign Virtual Route Extension
into the UCB Department Group
SV8100 Version 5000, UCB 5.1
and TSP 4.00 or higher.
Assign the SIP extensions for
Announce ports to the UCB
Department Group SV8100
Version 4000 (4.01), UCB 5.0
SP4 and TSP 3.03 or lower.
The time the system waits to seize
the next outside line after the
system releases an outside line.
Assigned Data
1
0 = Normal (Intercom
caller to busy
department member
hears busy)
1 = Circular (Intercom
callers to busy
department member
routes to idle member)
(default = 0)
0 = Last extension is
called and hunting is
stopped
1 = Circular
(default = 0)
64800 (seconds)
(default = 15)
0 = No queuing
1 = Hunting When
Busy
2 = Hunting When Not
Answered
3 = Hunting When
Busy or No Answer
(default = 0)
Department Groups
1~64
Priority 1-999
Default = All
extensions in
Department Group 1
with priority in port
order:
Port 1 priority = 1
Port 256 priority = 256
0~64800 (seconds)
(default = 1)
Set to 0
Issue 8.01
Level
2
3
2 - 1503

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents