2. Inspect the runout by supponing both ends of the
mainshaft. Rotate the mainshaft two complete
revolutions when measuring the runout. lf the
runout is more than the service limit. reolace the
mainshaft with a new one.
Standard:
0.02 mm (0.001 in.) max.
Service Limit: 0.05 mm (0.002 in.)
13-27