Compressor Thermal Protector - Honda Civic Service Manual

2002-2003 hatchback
Hide thumbs Also See for Civic:
Table of Contents

Advertisement

Compressor Thermal Protector
Replacement
1. Remove the bolt, the ground terminal (A), and the
holder (B). Disconnect the field coil connector (C).
then remove the thermal protector (D).
Replace the thermal protector (A) with a new one,
and apply silicone sealant (B) to the bottom of the
thermal Drotector.
A
3. lnstall in the reverse order of removal.
7.4 N.m
(0.75 kgf.m,
5 rbf.ftl
Compressor Relief Valve
Replacement
2 .
1 .
4 .
Recover the refrigerant with a recovery/recycling/
charging station (see page 21-53).
Remove the relief valve (A) and the O-ring (B). Plug
the opening to keep foreign mafter from entering
the system and the compressor oil from running
out.
A
9,8 N.m
(1.0 kgf m,7.2lbf.ft)
Clean the mating surfaces.
Install a new O-ring on the relief valve, and apply a
thin coat of refrigerant oil to the O-ring.
Remove the plug, and install and tighten the relief
valve.
Charge the system (see page 21-55).
21-51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2002 civic2003 civic

Table of Contents