WEC/VTC
30.
DTC Troubleshooting (cont'd)
Disconnect ECM connector B (24P)
Check for continuity between ECM connector
t e r m i n a l 8 1 5 a n d b o d y g r o u n d .
ECM CONNECTOR B {24P)
Wire side of female terminals
ls there continuity?
YES-Repair short in the wire between the VTEC
s o l e n o i d v a l v e a n d t h e E C M ( 8 1 5 ) . 1
NO Go to step 32.
11-126
32. Connect VTEC solenoid valve 2P connector
terminal No. 2 to body ground with a jumper wire.
VTEC SOLENOID VALVL
2P CONNECTOR
r-.'-r.---.1
t 1 t 2 l
+
JUMPER I VtS
WIRE
I IGRN/YEL)
I
Wire side of female terminals
Check for continuity between ECM connector
t e r m i n a l 8 1 5 a n d b o d y g r o u n d .
ECM CONNECTOR B {24PI
Wire side of female terminals
ls thete continuity?
YES Update the ECM if it does not have the latest
software, or substitute a known-good ECM, then
recheck (see page 11-6). lf the symptom/indication
goes away with a known-good ECM, replace the
o r i g i n a l E C M . I
NO Repair open in the wire between the VTEC
s o l e n o i d v a l v e a n d t h e E C M ( 8 1 5 ) . I