NEO 200s/400s User Guide
taken offline by phoning the host operator or other means of communication. Before
performing any service functions, ensure the host is not performing any data writing or
retrieval.
The Service Menu contains the following items:
• Library Verify – an overall library diagnostic
• Run Tests – other library diagnostics
• Service – diagnostics and procedures for servicing the drive
• Display Contrast – setting the display from light to dark
• Telnet Service Port – technical support use only
Service: Library Verify
This is an overall diagnostic that exercises all library components. To run the Library
Verify test, complete the following procedure.
1. On the Operator Control Panel, navigate to Service > Library Verify and start
diagnostic.
a. Push SELECT to highlight the drive field. Use UP and DOWN to select the drive.
b. Push DOWN to highlight Run.
c. Push SELECT to execute Library Verify.
2. When prompted by the Operator Control Panel display and the Mail Slot opens, insert
a blank or scratch data cartridge.
3. Close the Mail Slot by pushing it back into the library.
4. While the test is running, the Operator Control Panel will display library status.
• If the test PASSES, resume normal library operations.
• If the test FAILS, an error code will be displayed. Make note of the error, then
5. When prompted by the Operator Control Panel display and the Mail Slot opens,
remove the cartridge used in the test.
6. Close the Mail Slot by pushing it back into the library.
7. Use UP and DOWN to highlight Cancel. Press SELECT to exit Library Verify.
Service: Run Tests
The following library diagnostics are available in this menu:
10400367-001 04/2012
Push SELECT to complete the selection.
refer to
Chapter 7, "Troubleshooting."