Overland Storage NEO 200S User Manual page 133

Network storage
Hide thumbs Also See for NEO 200S:
Table of Contents

Advertisement

NEO 200s/400s User Guide
Error Code Description
92
VPD data have been restored from
EEPROM.
DB
External cooling fan error (fan motion
has stopped).
The subcode indicates which drive sled
fan is affected:
• Subcode 01: drive sled #1(bottom).
• Subcode 02: drive sled #2.
2
DC
I
C Bus Failure
DD
Power Supply x fan has failed;
Redundancy may be at risk.
The subcode indicates which power
supply fan is affected:
• Subcode 01: 1st PS fan from bottom.
• Subcode 02: 2nd PS fan from
bottom.
DF
Power Good signal changed from 2 to 1
Power Supplies.
F6
No drive installed. A drive has never
been installed.
10400367-001 04/2012
User Action
This is normal when the VPD has been restored EEPROM.
Refer to
"Isolating Drive Sled Problems" on page
Refer
to"Isolating a Power Supply Problem" on page
Install at least one drive.
©2012 Overland Storage, Inc.
Warning Events
7-9.
7-7.
8-12

Hide quick links: