NEO 200s/400s User Guide
• The Ready/Activity LED ( ) is illuminated any time the unit is powered ON and
functional. The Ready/Activity LED blinks whenever there is library or drive activity.
This LED will also blink when the unit is OFFLINE.
• The Clean LED ( ) is illuminated when either a cleaning requested or a cleaning
required flag has been issued by the drive. The LED is turned off after a successful
drive cleaning operation.
• The Attention LED ( ) indicates one of the following conditions.
Problem
Bad media
Drive sled issues
Redundant power supply failed Complete the following steps:
Power supply fan failure
• The Error LED ( ) turns ON when there is an unrecoverable drive or library failure.
An error message is displayed on the screen and the LED remains ON until the error
state is resolved.
NOTE: From the Operator Control Panel, run Service > Library Verify. If Library Verify runs

Input Modes

There are several ways to enter values in the different menu items. These values are
selectable predefined values, toggle values (for example, ON/OFF) and numerical values
like network addresses.
Selecting Predefined Values
1. To set the predefined values, press the SELECT button to select the menu item.
2. Using the UP and DOWN buttons, select one of the various predefined values for
that item.
3. As soon as the Operator Control Panel display shows the correct value, press the
SELECT key to apply the value.
10400367-001 04/2012
Action Required
1. Go to
2. Move the defective cartridge to the Mail Slot. (Operator
3. Open the Mail Slot to remove the defective cartridge.
Do one of the following:
• Install a different drive sled.
• Modify or resubmit Logical Library setting (Operator Control
Panel:
Interface:
• Restore defaults (Operator Control Panel:
Restore Defaults or Web User Interface: Configure
Library > Restore Defaults ).
1. Replace the failed power supply.
2. Cycle library power.
Replace the power supply.
without error, the Error LED turns off. If the error persists, recycle the power.
©2012 Overland Storage, Inc.
Monitor > Inventory to locate the defective
cartridge.
Control > Move Cartridges ).
Control Panel:
Control > Open I/O ).
(Operator Control Panel:
Configure > Logical Libraries or Web User
Configure Library > Logical Libraries ).