Step
12
Is there continuity between harness side connector
I–41 terminal 5 or I–42 terminal 11 and harness side
connector G–6 terminal 6?
13
Repair an open circuit between connector G–6 terminal
6 and connector I–41 terminal 5 or connector I–42
terminal 11.
Is the action complete?
Action
WIRING SYSTEM
Value(s)
Yes
—
Go to Step 13
—
Verify repair
8D–173
No
Replace the
alarm & relay
control unit
—